Review




Structured Review

Time Domain Corporation number of scr and scl data-points above the mean
Number Of Scr And Scl Data Points Above The Mean, supplied by Time Domain Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/number+of+scr+and+scl+data-points+above+the+mean/kurtosis+of+the+scr+and+scl/pmc10151757__Presentation_1-6-118-363
Average 90 stars, based on 1 article reviews
number of scr and scl data-points above the mean - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

other:

Article Title: Synergy through integration of digital cognitive tests and wearable devices for mild cognitive impairment screening
Article Snippet: Category Name Description Unit Time domain mean Mean of the SCR and SCL μS std Standard deviation of the SCR and SCL μS min/max Minimum and maximum of the SCR and SCL μS ptp Range (peak to peak) of SCR and SCL within a time interval μS sum Sum of the SCR and SCL values with a time interval μS energy Energy of the SCR and SCL μS2 skewness Skewness of the SCR and SCL / kurtosis Kurtosis of the SCR and SCL / peaks Number of SCR and SCL peaks with a time interval / rms Root mean square of the SCR and SCL μS line_integral Integral under the SCR and SCL curve μS.s n_above_mean Number of SCR and SCL data-points above the mean / n_below_mean Number of SCR and SCL data-points below the mean / n_sign_changes Number of changes in the SCR and SCL slope / iqr Interquartile range between the 25th and 75th percentile of the SCR and SCL μS iqr_5_95 Interquartile range between the 5th and 95th percentile of the SCR and SCL μS pct_5 5th percentile of the SCR and SCL / pct_95 95th percentile of the SCR and SCL / entropy Entropy of the SCR and SCL / perm_entropy Permutation entropy of the SCR and SCL / svd_entropy Singular value decomposition of the SCR and SCL entropy / Frequency domain sma Signal magnitude area of the frequency domain SCR and SCL μS energy Energy of the frequency domain SCR and SCL μS2 kurtosis Kurtosis of the frequency domain SCR and SCL / iqr Interquartile range of the frequency domain SCR and SCL μS/Hz spectral_power 5 spectral power magnitudes in the [0.05-0.55] Hz bands for the power density of the SCR and SCL μS2/Hz var_power Variance of the SCR and SCL spectral power μS2 Timefrequency domain mean Mean of the SCR’s and SCL’s MFC signal μS std Mean of the SCR’s and SCL’s MFC signal μS median Median of the SCR’s and SCL’s MFC signal μS iqr Interquartile range of the SCR’s and SCL’s MFC signal μS skewness Skewness of the SCR’s and SCL’s MFC signal / kurtosis Kurtosis of the SCR’s and SCL’s MFC signal / SCR timedomain features peaks Number of SCR peaks / rise_time Mean of the SCR peaks rise time s max_deriv Mean value of the maximum derivative of the SCR peaks μS/s amp Mean amplitude of the SCR peaks μS decay_time Mean of the SCR peaks decay time s scr_width Mean width of the SCR peaks s auc_mean Mean area-under-curves of the SCR peaks μS.s auc_sum Sum of the area-under-curves of the SCR peak μS.s Mel-Frequency Cepstrum (MFC), skin conductance level (SCL), and skin conductance response (SCR).



Similar Products

90
Time Domain Corporation number of scr and scl data-points above the mean
Number Of Scr And Scl Data Points Above The Mean, supplied by Time Domain Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/number+of+scr+and+scl+data-points+above+the+mean/kurtosis+of+the+scr+and+scl/pmc10151757__Presentation_1-6-118-363
Average 90 stars, based on 1 article reviews
number of scr and scl data-points above the mean - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results